ATOMIC AQUATICS FIRST AND SECOND STAGE REGULATORS MAINTENANCE PROCEDURES • 9/2003 9
SS1 SUPPLEMENT
Part 1. BCD Adapter Installation
Adapters:
A set of adapters is available for the SS1 to fit it to a wide range of hose sizes. Assembly is straightforward. There is
one o-ring (20-2114-00) common to each adapter that is included in the service kit.
Select the proper sized adapter for the particular BCD hose you have. The adapter may fit slightly snug but
never loose. Some manufacturers may have used different size hoses in different models.
Check the integrity of the BCD hose before installation. Rubber can become cracked or split with age. Refit with a new
hose from the manufacturer if it is damaged or deteriorated.
Cable Dump:
All adapters are supplied with a cable pull pin. Each pin is a specific length to fit the specific adapter. Make certain you
use the correct pin. The correct pin should be approximately the same length as the diameter of the adapter and not
protrude from it when installed.
The adapters must be secured to the hose with at least one cable tie and preferably two if room allows. We recommend
gluing in place for added security using neoprene (wetsuit) cement. Water test all connections for leaks. Fully inflate the
BCD and test operation of the cable dump if installed. The cable dump should not leak when the BCD is fully inflated
and should release air when pulled slightly.
Part 2. SS1 Disassembly
1. Serial Number location.
The serial number is located beneath the rubber mouthpiece. Clip the plastic clamp and remove the mouthpiece to
read the number. Note: The mouthpiece is specifically designed for the SS1. Using other mouthpieces can change
the venturi characteristics and make the SS1 susceptible to free-flow or increased sensitivity in the water.
2. Removal of Front Cover and Diaphragm.
Position the SS1 on a firm surface with a towel under it to protect it. Using a short, flat bladed screwdriver, insert
the blade into one of the elongated slots in the plastic body. Push down firmly to unlock the tab of the cover
retainer. Repeat to unlock all 4 tabs then withdraw the cover retainer, cover, inner ring and diaphragm.
Standard 1.0" adapter assy. This is the most common size and used on
most BCDs. Fits most Scubapro
, SeaQuest
, Zeagle
, TUSA
, IDI
, Deep
Outdoors
and others. This adapter is assembled with the adapter sleeve as
an integral component.
Medium Adapter. Fits 3/4" to 13/16 hoses. Fits most Mares
. Adapter
sleeve must be installed before inserting into hose.
Small Adapter. Fits 11/16" to 3/4 hoses. Fits smaller diameter Oceanic
and US Divers
. Adapter sleeve must be installed before inserting into hose.